Approaches implemented in refrigerant library
Currently, one modeling approach is implemented in the
refrigerants' library:
-
Hybrid Approach: The hybrid approach uses the both the
Helmholtz equation of state (EoS) and polynomial functions. The
polynomial functions are used to avoid iterations that normally
occur while using modeling approaches only based on the EoS.
Assumptions and limitations:
Up to this point, the modeling approaches implemented in the
library are only valid for pure and pseudo-pure refrigerants.
Consequently, calculation procedures of pseudo-pure refrigerants
are only roughly valid within the two-phase region.
Contents
- October 14, 2017, by Mirko Engelpracht:
First implementation (see issue
408).