modelCocurrentHeatExchanger

Cocurrent heat exchanger from ScalableTestSuite (adapted for balanced array equations)

Extends from Modelica.Icons.Example.

Parameters

TypeNameDefaultDescription
IntegerN10number of nodes
SI.LengthL10length of the channels
SI.MassFlowRatewB1mass flow rate of fluid B
SI.AreaareaA5e-5cross sectional area of channel A
SI.AreaareaB5e-5cross sectional area of channel B
SI.DensityrhoA1000density of fluid A
SI.DensityrhoB1000density of fluid B
SI.SpecificHeatCapacitycpA4200specific heat capacity of fluid A
SI.SpecificHeatCapacitycpB4200specific heat capacity of fluid B
SI.SpecificHeatCapacitycpW2000specific heat capacity of the wall
SI.CoefficientOfHeatTransfergammaA4000heat transfer coefficient of fluid A
SI.CoefficientOfHeatTransfergammaB10000heat transfer coefficient of fluid B
SI.Lengthomega0.1perimeter

Components

TypeNameDefaultDescription
SI.Lengthllength of each wall segment
SI.MassFlowRatewAmass flow rate of fluid A
SI.HeatFlowRate[N - 1]QAheat flow rate of fluid A in the segments
SI.HeatFlowRate[N - 1]QBheat flow rate of fluid B in the segments
SI.Temperature[N]TAtemperature nodes on channel A
SI.Temperature[N]TBtemperature nodes on channel B
SI.Temperature[N - 1]TAtildetemperature states on channel A
SI.Temperature[N - 1]TBtildetemperature states on channel B
SI.Temperature[N - 1]TWtemperatures on the wall segments
SI.HeatFlowRateQtotAtotal heat flow rate of fluid A
SI.HeatFlowRateQtotBtotal heat flow rate of fluid B

Revisions

  • 2015-11-05 by Kaan Sezginer, Francesco Casella: Initial version in the ScalableTestSuite.
  • 2025-05-02 by Hilding Elmqvist (Mogram AB): Adapted so that it can be processed without expanding arrays.