This partial model is an extension of the model of a generalized
electric machine PartialBasicMachine. Hence, it consists
of the same mechanical subsystem. The model defines a two-phase
machine. The electrical subsystem contains four electrical pins of
type ComplexPin.
The rms values of the branch voltages and branch currents are
calculated from the corresponding phasors. The model does not
include any current phasor balance. Two values of active and
reactive power (for each branch) are computed and made available
via two output signals.
Remark:
This partial model is suitable only for modeling two-phase
machines.