modelElecSystem
RLC filter for WT (IEC N°61400-27-1)
Extends from Dynawo.Electrical.Controls.Basics.SwitchOff.SwitchOffTransformer (Switch-off signal for a transformer).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | NbSwitchOffSignals (from SwitchOffLogic) | Number of switch-off signals to take into account in inputs | |
| Boolean | SwitchOffSignal10 (from SwitchOffLogic) | false | Initial switch-off signal 1 |
| Boolean | SwitchOffSignal20 (from SwitchOffLogic) | false | Initial switch-off signal 2 |
| Boolean | SwitchOffSignal30 (from SwitchOffLogic) | false | Initial switch-off signal 3 |
| Boolean | Running0 (from SwitchOffLogic) | if NbSwitchOffSignals >= 3 then not (SwitchOffSignal10 or SwitchOffSignal20 or SwitchOffSignal30) elseif NbSwitchOffSignals >= 2 then not (SwitchOffSignal10 or SwitchOffSignal20) else not SwitchOffSignal10 | Indicates if the component is initially running or not |
| Constants.state | State0 (from SwitchOffTransformer) | Constants.state.Closed | Start value of connection state |
| Types.ApparentPowerModule | SNom | Nominal converter apparent power in MVA | |
| Electrical | |||
| Types.PerUnit | BPu | Shunt susceptance in pu (base UNom, SNom) | |
| Types.PerUnit | GPu | Shunt conductance in pu (base UNom, SNom) | |
| Types.PerUnit | RPu | Serial resistance in pu (base UNom, SNom) | |
| Types.PerUnit | XPu | Serial reactance in pu (base UNom, SNom) | |
| Initialization | |||
| Types.ComplexCurrentPu | i10Pu | i20Pu + Complex(GPu, BPu)*u10Pu | Initial complex current at terminal 1 in pu (base UNom, SNom) (receptor convention) |
| Types.ComplexCurrentPu | i20Pu | Initial complex current at terminal 2 in pu (base UNom, SNom) (generator convention) | |
| Types.ComplexVoltagePu | u10Pu | u20Pu + Complex(RPu, XPu)*i20Pu | Initial complex voltage at terminal 1 in pu (base UNom) |
| Types.ComplexVoltagePu | u20Pu | Initial complex voltage at terminal 2 in pu (base UNom) | |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Blocks.Interfaces.BooleanInput | switchOffSignal1 (from SwitchOffLogic) | Switch-off signal 1 | |
| Modelica.Blocks.Interfaces.BooleanInput | switchOffSignal2 (from SwitchOffLogic) | Switch-off signal 2 | |
| Modelica.Blocks.Interfaces.BooleanInput | switchOffSignal3 (from SwitchOffLogic) | Switch-off signal 3 | |
| Modelica.Blocks.Interfaces.BooleanOutput | running (from SwitchOffLogic) | Indicates if the component is running or not | |
| Dynawo.Connectors.ACPower | terminal1 | terminal 1, complex voltage and current in pu (base UNom, SnRef) (receptor convention) | |
| Dynawo.Connectors.ACPower | terminal2 | terminal 2, complex voltage and current in pu (base UNom, SnRef) (receptor convention) | |
| Modelica.Blocks.Interfaces.RealOutput | i1ImPu | Imaginary component of the current at terminal 1 in pu (base UNom, SNom) (receptor convention) | |
| Modelica.Blocks.Interfaces.RealOutput | i1RePu | Real component of the current at terminal 1 in pu (base UNom, SNom) (receptor convention) | |
| Modelica.Blocks.Interfaces.RealOutput | i2ImPu | Imaginary component of the current at terminal 2 in pu (base UNom, SNom) (generator convention) | |
| Modelica.Blocks.Interfaces.RealOutput | i2RePu | Real component of the current at terminal 2 in pu (base UNom, SNom) (generator convention) | |
| Modelica.Blocks.Interfaces.RealOutput | u1ImPu | Imaginary component of the voltage at terminal 1 in pu (base UNom) | |
| Modelica.Blocks.Interfaces.RealOutput | u1RePu | Real component of the voltage at terminal 1 in pu (base UNom) | |
| Modelica.Blocks.Interfaces.RealOutput | u2ImPu | Imaginary component of the voltage at terminal 2 in pu (base UNom) | |
| Modelica.Blocks.Interfaces.RealOutput | u2RePu | Real component of the voltage at terminal 2 in pu (base UNom) |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Constants.state | state (from SwitchOffTransformer) | Transformer connection state | |
| Types.ComplexCurrentPu | i1Pu | Complex current at terminal 1 in pu (base UNom, SNom) (receptor convention) | |
| Types.ComplexCurrentPu | i2Pu | Complex current at terminal 2 in pu (base UNom, SNom) (generator convention) | |
| Types.ComplexVoltagePu | u1Pu | Complex voltage at terminal 1 in pu (base UNom) | |
| Types.ComplexVoltagePu | u2Pu | Complex voltage at terminal 2 in pu (base UNom) |