modelWTGCurrentSource_INIT

Initialization model for WECC WTG models with a current source as interface with the grid

Extends from Dynawo.Electrical.Controls.WECC.BaseClasses_INIT.WECCPlantCurrentSource_INIT (Initialization model for WECC BESS, PV and WT models with a current source as interface with the grid).

Parameters

TypeNameDefaultDescription
Types.PerUnitRPu (from ParamsLvTfo)if ConverterLVControl then 1e-5 else RLvTrPuSerial resistance between injector output and LvTfo in pu (base UNom, SNom). Including source resistance for voltage source.
Types.PerUnitXPu (from ParamsLvTfo)if ConverterLVControl then 1e-5 else XLvTrPuSerial reactance between injector output and LvTfo in pu (base UNom, SNom). Including source resistance for voltage source.
Types.ApparentPowerModuleSNom (from ParamsPCS)Nominal apparent power in MVA
Types.PerUnitBPcsPu (from ParamsPCS)if PPCLocal then BMvHvPu else 1e-5Shunt susceptance between converter terminal and model's output terminal in pu (base UNom, SNom)
Types.PerUnitGPcsPu (from ParamsPCS)if PPCLocal then GMvHvPu else 1e-5Shunt conductance between converter terminal and model's output terminal in pu (base UNom, SNom)
Types.PerUnitRPcsPu (from ParamsPCS)if PPCLocal and ConverterLVControl then RLvTrPu + RMvHvPu elseif PPCLocal and not ConverterLVControl then RMvHvPu elseif not PPCLocal and ConverterLVControl then RLvTrPu else 1e-5Serial resistance between converter terminal and model's output terminal in pu (base UNom, SNom)
Types.PerUnitXPcsPu (from ParamsPCS)if PPCLocal and ConverterLVControl then XLvTrPu + XMvHvPu elseif PPCLocal and not ConverterLVControl then XMvHvPu elseif not PPCLocal and ConverterLVControl then XLvTrPu else 1e-5Serial reactance between converter terminal and model's output terminal in pu (base UNom, SNom)
Types.ActivePowerPuPPcc0Pu (from WECCPlantCurrentSource_INIT)Initial active power at the external bus controlled by the PPC (used when PPCLocal = false) (receptor convention, base UNom, SnRef) (only if the PCS is defined outside of the model)
Types.ReactivePowerPuQPcc0Pu (from WECCPlantCurrentSource_INIT)Initial reactive power at the external bus controlled by the PPC (used when PPCLocal = false) (receptor convention, base UNom, SnRef) (only if the PCS is defined outside of the model)
Types.VoltageModulePuUPcc0Pu (from WECCPlantCurrentSource_INIT)Start value of voltage magnitude at PPC regulated bus in pu (bae UNom)
Types.AngleUPhasePcc0 (from WECCPlantCurrentSource_INIT)1Start value of voltage phase angle at PPC regulated bus in rad
Types.ActivePowerPuP0Pu (from WECCPlantCurrentSource_INIT)Start value of active power at converter terminal in pu (receptor convention) (base SnRef)
Types.ReactivePowerPuQ0Pu (from WECCPlantCurrentSource_INIT)Start value of reactive power at converter terminal in pu (receptor convention) (base SnRef)
Types.VoltageModulePuU0Pu (from WECCPlantCurrentSource_INIT)Start value of voltage magnitude at converter terminal in pu (bae UNom)
Types.AngleUPhase0 (from WECCPlantCurrentSource_INIT)Start value of voltage phase angle at converter terminal in rad
LV transformer
Types.PerUnitRLvTrPu (from ParamsLvTfo)Serial resistance of LV transformer in pu (base UNom, SNom). Including source resistance for voltage source.
Types.PerUnitXLvTrPu (from ParamsLvTfo)Serial reactance of LV transformer in pu (base UNom, SNom). Including source reactance for voltage source.
BooleanConverterLVControl (from ParamsLvTfo)If true, the converter is controlling at its output (LV side of its transformer), if false, after its transformer (MV side)
MV network + MV/HV transformer
Types.PerUnitBMvHvPu (from ParamsPCS)0Shunt susceptance of internal MV network + MV/HV transformer in pu (base UNom, SNom)
Types.PerUnitGMvHvPu (from ParamsPCS)0Shunt conductance of internal MV network + MV/HV transformer in pu (base UNom, SNom)
Types.PerUnitRMvHvPu (from ParamsPCS)0Serial resistance of internal MV network + MV/HV transformer in pu (base UNom, SNom)
Types.PerUnitXMvHvPu (from ParamsPCS)0Serial reactance of internal MV network + MV/HV transformer in pu (base UNom, SNom)
Types.PerUnitrTfoPu (from ParamsPCS)1Transformation ratio in pu: UWT_terminal/UWTG_terminal in no load conditions
BooleanPPCLocal (from ParamsPCS)If true, the Power Park Control is controlling at model's output terminal, if false, at a remote terminal using external measurements
Torque control
Types.PerUnitP101st power point for extrapolation table
Types.PerUnitSpd111st speed point for extrapolation table
Types.PerUnitP212nd power point for extrapolation table
Types.PerUnitSpd212nd speed point for extrapolation table
Types.PerUnitP323rd power point for extrapolation table
Types.PerUnitSpd313rd speed point for extrapolation table
Types.PerUnitP434th power point for extrapolation table
Types.PerUnitSpd414th speed point for extrapolation table

Components

TypeNameDefaultDescription
Types.ComplexCurrentPui0Pu (from WECCPlantCurrentSource_INIT)Start value of complex current at terminal in pu (base UNom, SnRef) (receptor convention)
Types.PerUnitId0Pu (from WECCPlantCurrentSource_INIT)Start value of d-axis current at injector in pu (base UNom, SNom) (generator convention)
Types.ComplexPerUnitiConv0Pu (from WECCPlantCurrentSource_INIT)Start value of complex current at converter terminal in pu (base UNom, SNom) (generator convention)
Types.ComplexPerUnitiInj0Pu (from WECCPlantCurrentSource_INIT)Start value of complex current at injector in pu (base UNom, SNom) (generator convention)
Types.PerUnitIq0Pu (from WECCPlantCurrentSource_INIT)Start value of q-axis current at injector in pu (base UNom, SNom) (generator convention)
Types.ComplexPerUnitiPcc0Pu (from WECCPlantCurrentSource_INIT)Start value of complex current at external PCC in pu (used when PPCLocal = false, meaning the PCS is defined outside of the model) (receptor convention) (base UNom, SnRef)
Types.PerUnitPInj0Pu (from WECCPlantCurrentSource_INIT)Start value of active power at injector in pu (base SNom) (generator convention)
Types.ActivePowerPuPConv0Pu (from WECCPlantCurrentSource_INIT)Start value of active power at converter terminal in pu (base SNom) (generator convention)
Types.PerUnitPF0 (from WECCPlantCurrentSource_INIT)Start value of power factor
Types.PerUnitQInj0Pu (from WECCPlantCurrentSource_INIT)Start value of reactive power at injector in pu (base SNom) (generator convention)
Types.ReactivePowerPuQConv0Pu (from WECCPlantCurrentSource_INIT)Start value of reactive power at converter terminal in pu (base SNom) (generator convention)
Types.ComplexPerUnits0Pu (from WECCPlantCurrentSource_INIT)Start value of complex apparent power at terminal in pu (base SnRef) (receptor convention)
Types.ComplexPerUnitsConv0Pu (from WECCPlantCurrentSource_INIT)Start value of complex apparent power at converter in pu (base SNom) (generator convention)
Types.ComplexPerUnitsInj0Pu (from WECCPlantCurrentSource_INIT)Start value of complex apparent power at injector in pu (base SNom) (generator convention)
Types.ComplexPerUnitsPcc0Pu (from WECCPlantCurrentSource_INIT)Start value of complex apparent power at external PCC in pu (used when PPCLocal = false, meaning the PCS is defined outside of the model) (receptor convention) (base UNom, SnRef)
Types.ComplexVoltagePuu0Pu (from WECCPlantCurrentSource_INIT)Start value of complex voltage at terminal in pu (base UNom)
Types.VoltageModulePuUControl0Pu (from WECCPlantCurrentSource_INIT)Initial voltage amplitude at the point controlled by the PPC (either model's output terminal or external PCC) in pu (base UNom)
Types.VoltageModulePuUConv0Pu (from WECCPlantCurrentSource_INIT)Start value of voltage module at converter terminal in pu (base UNom)
Types.ComplexPerUnituConv0Pu (from WECCPlantCurrentSource_INIT)Start value of complex voltage at converter terminal in pu (base UNom)
Types.VoltageModulePuUInj0Pu (from WECCPlantCurrentSource_INIT)Start value of voltage module at injector in pu (base UNom)
Types.ComplexPerUnituInj0Pu (from WECCPlantCurrentSource_INIT)Start value of complex voltage at injector in pu (base UNom)
Types.AngleUPhaseConv0 (from WECCPlantCurrentSource_INIT)Value of voltage phase angle at converter terminal in rad
Types.ComplexVoltagePuuPcc0Pu (from WECCPlantCurrentSource_INIT)Initial voltage module at the external bus controlled by the PPC (used when PPCLocal = false, meaning the PCS is defined outside of the model) (base UNom)
Types.PerUnitPm0Pu (from WECCPlantCurrentSource_INIT)Initial mechanical power in pu (base SNom)
Types.AngularVelocityPuomegaRefWTGQ0PuStart value of reference angular frequency of torque control in pu (base omegaNom)
Modelica.Blocks.Tables.CombiTable1DcombiTable1D
Modelica.Blocks.Sources.RealExpressionrealExpression