Single phase flow calculation using Medium's physical properties,
and adiabatic, isentropic, flow
Allows the
calculation of the flow or the area of a safety relief valve or
disk. It uses isentropic calculation between the inlet, supposed
with velocity equal to 0, and the orifice. The gas flow can be
chocked or not, and all the calculations are done with the physical
properties calculated by the Medium, except the possibility of
manual entering of the isentropic coefficient. Correction
coefficients are applied for backpressure and for viscosity,
according to the API 520 methodology. It is capable for biphasic
flow calculation, but the model SafetyValveFlash, that conforms to
the API recommenations, is probably more adequate.
Two thermodynamic
states are declared at the orifice outlet, both isentropics with
the inlet. One of them at the discharge pressure of the valve, the
other adjusted to obtain sonic speed at the orifice. If the
discharge pressure is below the obtained critical pressure, the
flow is taken from the critical calculation, if not from the
discharge pressure calculation.
Generated at 2026-04-14T18:18:34Z by OpenModelicaOpenModelica 1.26.3 using
GenerateDoc.mos