This example compares a time transient and a quasi static model
of a multi phase induction machine. At start time tOn
a transient and a quasi static multi phase voltage source are
connected to an induction machine. The machines starts from
standstill, accelerating inertias against load torque quadratic
dependent on speed, finally reaching nominal speed.
imc.tauElectrical: transient torqueimc.wMechanical: transient speedimc.tauElectrical against
imc.wMechanical: transient torque speed
characteristicimcQS.tauElectrical: quasi static torqueimcQS.wMechanical: quasi static speedimcQS.tauElectrical against
imcQS.wMechanical: quasi static torque speed
characteristiccurrentRMSsensor.I: quasi RMS stator current of
transient machinecurrentRMSSensorQS.I: RMS stator current of quasi
static machineimc.stator.electroMagneticConverter.abs_Phi:
magnitude of stator flux of transient machineimcQS.stator.electroMagneticConverter.abs_Phi:
magnitude of stator flux of quasi static machine