interior opaque wall between two zones
This is a wall model that should be used to simulate a wall or
floor between two zones. See
IDEAS.Buildings.Components.Interfaces.PartialOpaqueSurface for
equations, options, parameters, validation and dynamics that are
common for all surfaces.
Typical use and important parameters
Each propsbus needs to be connected to a zone, which may be the
same zone.
Note that this model is not symmetric: the convection equations
depend on the inclination inc, which is turned 180
degrees between both side. The value of inc is applied
to the right side of the model (propsBus_a).
Parameter hasCavity can be set to true
to simulate heat transfer through a cavity such as an open door in
a simplified way. The cavity height h and width
w then have to be specified. We assume that the value
of A excludes the surface area of the cavity.
- February 5, 2025, by Klaas De Jonge:
Support was added to, optionally, check vertical heights in the
two-port airflow implementation that acounts for the floor
thicknesses. See #1338 and
#1417
- January 24, 2025, by Klaas De Jonge:
Add dummy connections for hzone and
hfloor in propsbus_b to avoid translation
warnings. See #1402
- November 7, 2024, by Anna Dell'Isola and Jelger Jansen:
Update calculation of transmission design losses. See #1337
- October 30, 2024, by Klaas De Jonge:
Modifications for stack-effect interzonal airflow heights.
- Februari 18, 2024, by Filip Jorissen:
Modifications for supporting trickle vents and interzonal
airflow.
- July 9, 2023, by Filip Jorissen:
Replaced door by operable door.
- August 2, 2022, by Filip Jorissen:
Activating thermal model when using OnePorts. See #1291
- August 10, 2020, by Filip Jorissen:
Modifications for supporting interzonal airflow. See #1066
- July 29, 2020, by Filip Jorissen:
Removed duplicate definition of port_emb. See #1158
- October 13, 2019, by Filip Jorissen:
Refactored the parameter definition of inc and
azi by adding the option to use radio buttons. See
#1067
- August 10, 2018 by Damien Picard:
Set nWin final to 1 as this should only be used for windows. See
#888.
- May 21, 2018, by Filip Jorissen:
Added model for air flow through cavity. See #822.
- January 2, 2017, by Filip Jorissen:
Updated icon layer.
- October 22, 2016, by Filip Jorissen:
Revised documentation for IDEAS 1.0.
- February 10, 2016, by Filip Jorissen and Damien Picard:
Revised implementation: cleaned up connections and partials.
- June 14, 2015, Filip Jorissen:
Adjusted implementation for computing conservation of energy.
Generated at 2026-04-15T18:18:36Z by OpenModelicaOpenModelica 1.26.3 using