This model validates the thermal performance of the PVT_UN collector, an uncovered and uninsulated PVT collector, using a long-term dataset from a test bench in Austria (Veynandt et al., 2023).
The model uses the quasi-dynamic ISO 9806 formulation and includes:
c1,
c2)c3,
c6)c4)c5)The dataset includes days with several hours of high wind speeds up to 10–12 m/s, which significantly increase convective losses. Additionally, the circulation pump remains active throughout the test period, even when thermal output is negative—unlike real-world systems, which would deactivate the pump under such conditions.
As a result, the raw energy deviation of +53.1 % is not a meaningful indicator of model performance. When filtered to periods with positive simulated thermal output, the deviation improves to +6.85 % (Meertens et al., 2025). This filtered metric better reflects the model's accuracy under realistic operating conditions.