Extension of IDEAS.Buildings.Components.Zone that supports zone linearisation. The model is therefore configured to used the well-mixed air model with the temperature as preferred state of the mixing volume and using IDEAS.Buildings.Components.InterzonalAirFlow.n50FixedPressure for the air infiltration.
An assert statement is added to ensure that the user only uses
the medium IDEAS.Media.Specialized.DryAir since the
linearization does not support other type of media.
IDEAS.Buildings.Components.ZoneAirModels.WellMixedAir