Version_0_3_0
Major changes compared to v0.2.0 are:
- Added code for checking conservation of energy
- Added options for linear/non-linear radiative heat exchange and
convection for exterior and interior faces of walls and
floors/ceilings. Respective correlations have been changed.
- Improved overall efficiency and reduced warnings.
- The emissivity of window coatings must now be specified as a
property of the solid (glass sheet) and not as a property of the
gas between the glass sheets. This is only relevant if you create
your own glazing.
- Merged Annex 60 library up to commit d7749e3
- Expanded unit tests
- Improved implementation of Koschenz's model for TABS and added
an option to discretize TABS sections.
- Added new building shade components.
- Removed inefficient code that would lead to numerical Jacobians
in the grid.
- Added new AC and DC electrical models.
Generated at 2026-04-14T18:18:34Z by OpenModelicaOpenModelica 1.26.3 using