blockF2i
Transform reference force to reference current
Extends from Modelica.Blocks.Interfaces.SISO (Single Input Single Output continuous control block).
Information
Calculates reference current from reference force, either using steady-state position or actual position of magnet. Additionally, the maximum admissible force is calculated from the maximum admissible current.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | k | 17.31E-9 | Force per current and distance^pd |
| SI.Current | iC | 0 | Equivalent current describing force between pm and iron core without coil current |
| Integer | pd | 4 | Power of distance to calculate force |
| SI.Current | iMax | 1 | Max. current |
| Boolean | useSteadyStatePosition | false | Otherwise actual position |
| SI.Position | d0 | -0.02 | Steady state position below coil |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| RealInput | u (from SISO) | Connector of Real input signal | |
| RealOutput | y (from SISO) | Connector of Real output signal | |
| Modelica.Blocks.Interfaces.RealInput | d | Connector of Real input signal | |
| Modelica.Blocks.Interfaces.RealOutput | fMax | Connector of Real output signal | |
| Modelica.Blocks.Interfaces.RealOutput | fMin | Connector of Real output signal |