Electrical excited synchronous machine with optional damper cage
The symmetry of the stator is assumed. For rotor asymmetries can
be taken into account by different resistances and stray
inductances in the d- and q-axis. The machine models take the
following loss effects into account:
- heat losses in the temperature dependent stator winding
resistances
- heat losses in the temperature dependent excitation winding
resistance
- optional, when enabled: heat losses in the temperature
dependent damper cage resistances
- brush losses in the excitation circuit
- friction losses
- core losses (only eddy current losses, no hysteresis
losses)
- stray load losses
See also
SM_PermanentMagnet,
SM_ReluctanceRotor,