modelPilink2
Pilink transmission line model built using Basic Components
Extends from Partials.PilinkBase (Pilink).
Information
Transmission line modelled in pi-equivalent form according to [1,pp. 44-45] realized using the Impedance and Admittance submodels. For numerical reasons, the R+jX must not be set equal to zero. --- [1] J. Machowski, J.W. Bialek, and J.R. Bumby, Power System Dynamics and Stability, Number ISBN 0-471-97174. Wiley, 1993.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| ObjectStab.Base.Resistance | R (from PilinkBase) | 0.0 | Series Resistance |
| ObjectStab.Base.Reactance | X (from PilinkBase) | 0.1 | Series Reactance |
| ObjectStab.Base.Susceptance | B (from PilinkBase) | 0.1 | Shunt Susceptance |
| ObjectStab.Base.Conductance | G (from PilinkBase) | 0.0 | Shunt Conductance |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| ObjectStab.Base.Pin | T1 (from TwoPin) | ||
| ObjectStab.Base.Pin | T2 (from TwoPin) |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| ObjectStab.Network.Impedance | Imp | ||
| ObjectStab.Network.Admittance | T2Adm | ||
| ObjectStab.Network.Admittance | T1Adm | ||
| ObjectStab.Network.Ground | GT1 | ||
| ObjectStab.Network.Ground | GT2 |