modelReservoir

Thermal reservoir for discretized aggregate

Information

This model allows a specified amount of heat flow rate to be "injected" into a thermal system or specify a certain temperature reservoir.
In case of a heat reservoir, the amount of heat at each cell is given by Q0/N.
The heat flows into the component to which the component PrescribedHeatFlow is connected, if the input signal is positive.

Author: Haiko Steuer SCD
Checked by:
Protection class:
Used Dymola version:
Copyright © 2007 Siemens AG, PG EIP12. All rights reserved.

This model is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY. For details see disclaimer

Parameters

TypeNameDefaultDescription
IntegerN2Number of cells
SiemensPower.Boundaries.Types.reservoirreservoirTypereservoir.heat
RealT_set500Fixed temperature
SiemensPower.Units.HeatFlowRateQ_flow_set0Fixed heat flow rate(overall)

Connectors

TypeNameDefaultDescription
Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_b[N]portsHeat output distribution

Components

TypeNameDefaultDescription
SiemensPower.Units.Temperature[N]T
SiemensPower.Units.HeatFlowRate[N]Q_flow

Revisions

  • December 2006, added by Haiko Steuer