modelCooler
Extends from SolarTherm.Media.CO2.PropCO2.
Information
The cooler is thought to be a dry-air cooling device. The outlet temperature of the CO2 is imposed as max(T_low_cycle,T_amb+3). The variation of the ambiant temperature is taken into account in the estimation of the electricity demand for the fans, such as: P_cooling*deltaT/Q_cooler is a constant, deltaT being the average of the temperature of the CO2 and the ambiant, and Q_cooler the energy to withdraw.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| SI.ThermodynamicTemperature | T_amb_des | 40 + 273.15 | Ambiant temperature in Kelvin at design point |
| SolarTherm.Types.Conductance | UA_cooler | Conductance of the cooler in W/K | |
| SI.ThermodynamicTemperature | T_low | 55 + 273.15 | |
| SI.Power | P_nom_des | 164000 | |
| Integer | N_cool | 15 | |
| Real | deltaT_design | 15 | Difference between ambient and outlet CO2 temperature |
| SolarTherm.Types.Conductance[N_cool - 1] | UA_dis | Conductance of the cooler per sub-HX | |
| SI.Power | P_cool_des | power necessary to cool down at design point | |
| SI.SpecificEnthalpy | h_in_des | ||
| SI.SpecificEnthalpy | h_out_des | ||
| SI.AbsolutePressure | p_in_des | ||
| SI.AbsolutePressure | p_out_des | ||
| SI.MassFlowRate | m_des | ||
| SI.HeatFlowRate | Q_cooler_des | ||
| MedPB.ThermodynamicState | state_des | Thermodynamic State at the i-th position | |
| SI.SpecificEnthalpy | h_CO2_des | ||
| Real | deltaT_des | difference with the ambiant air at the inlet and outlet | |
| SI.HeatFlowRate | Q_dis_des | Heat flow rate dispatched per sub-HX in the cooler | |
| SI.ThermodynamicTemperature | T_CO2_des |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Fluid.Interfaces.FluidPort_a | port_a | ||
| Modelica.Fluid.Interfaces.FluidPort_b | port_b |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Blocks.Types.ExternalCombiTable2D | tableIDh_p_s (from PropCO2) | Modelica.Blocks.Types.ExternalCombiTable2D(tableName = "Enthalpy", fileName = Modelica.Utilities.Files.loadResource("modelica://SolarTherm/Data/CO2/Props_from_P_S.txt"), table = fill(0.0, 0, 2), smoothness = Modelica.Blocks.Types.Smoothness.LinearSegments) | |
| Modelica.Blocks.Types.ExternalCombiTable2D | tableIDd_p_h (from PropCO2) | Modelica.Blocks.Types.ExternalCombiTable2D(tableName = "Density", fileName = Modelica.Utilities.Files.loadResource("modelica://SolarTherm/Data/CO2/Props_from_P_H.txt"), table = fill(0.0, 0, 2), smoothness = Modelica.Blocks.Types.Smoothness.LinearSegments) | |
| Modelica.Blocks.Types.ExternalCombiTable2D | tableIDT_p_h (from PropCO2) | Modelica.Blocks.Types.ExternalCombiTable2D(tableName = "Temperature", fileName = Modelica.Utilities.Files.loadResource("modelica://SolarTherm/Data/CO2/Props_from_P_H.txt"), table = fill(0.0, 0, 2), smoothness = Modelica.Blocks.Types.Smoothness.LinearSegments) | |
| Modelica.Blocks.Types.ExternalCombiTable2D | tableIDh_p_T (from PropCO2) | Modelica.Blocks.Types.ExternalCombiTable2D(tableName = "Enthalpy", fileName = Modelica.Utilities.Files.loadResource("modelica://SolarTherm/Data/CO2/Props_from_P_T.txt"), table = fill(0.0, 0, 2), smoothness = Modelica.Blocks.Types.Smoothness.LinearSegments) | |
| Boolean | m_sup | ||
| SI.ThermodynamicTemperature | T_amb | Ambiant temperature in Kelvin | |
| MedPB.ThermodynamicState | state_a | Thermodynamic State at the entrance | |
| MedPB.ThermodynamicState | state_b | Thermodynamic State at the outlet | |
| Real | deltaT | ||
| SI.HeatFlowRate | Q_cooler | ||
| SI.Power | P_cooling |
Contents
| Name | Description |
|---|---|