GridInput models the input of electrical power from
renewable sources, such as photovoltaic (PV) and wind farms, into
an electrical grid. The model calculates the net electrical power
input based on reference power data, curtailment, and user-defined
parameters.
The GridInput model has the following connectors and
parameters:
- Parameters:
- pv_file: File with the reference PV farm output.
- wind_file: File with the reference Wind farm
output.
- P_elec_min: Minimum power input, in Watts. Default: 25e6
W.
- P_elec_max: Maximum power input, in Watts. Default:
100e6 W.
- pv_fraction: PV fraction of renewable input at design.
Default: 0.5.
- P_elec_pv_ref_size: PV farm reference size, in Watts.
Default: 50e6 W.
- P_elec_wind_ref_size: Wind farm reference size, in
Watts. Default: 50e6 W.
- Connectors:
- P_elec_net: Net electrical power output to the
grid.
- curtail: Input for curtailment control.
- P_schedule: Input for controlling power scheduling.
- electricity: Output for the electrical power input to
the grid.
- on_renewable: Output indicating whether the power input
is from renewable sources.
Generated at 2026-04-15T18:18:36Z by OpenModelicaOpenModelica 1.26.3 using