modelOffTimer_DerivativeInformed

Records the time since the input changed to false considering the slope of the signal

Extends from Modelica.Blocks.Icons.PartialBooleanBlock (Basic graphical layout of logical block).

Information

Timer that starts at the initial time with a value of 0, and gets reset each time the input signal switches to false.

For example, if the simulation starts at t = 10 and at t=11, the input becomes false, then the timer outputs y=t-10 for t < 11, and y=t-11 afterwards, unless the input becomes false again.

Parameters

TypeNameDefaultDescription
BooleanpositiveDerivativetrueSpecify direction upon when trigger is reset

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.BooleanInputuConnector of Boolean input signal
Modelica.Blocks.Interfaces.RealOutputyConnector of Real output signal
Modelica.Blocks.Interfaces.RealInputs

Revisions

Modified from IBPSA Library