modelPumpImpellerSize

Example 14-2: Selection of Pump Impeller Size

Extends from TRANSFORM.Icons.Example (Icon for runnable examples).

Information

Source:

1. Y. A. ÇENGEL and J. M. CIMBALA, Fluid Mechanics: Fundamentals and Applications, 2. ed, McGraw-Hill, Higher Education, Boston (2010).

Parameters

TypeNameDefaultDescription
SI.Heighthead_nominalSItf.Conversions.Functions.Distance_m.from_ft(24)
SI.VolumeFlowRateV_flow_nominalSItf.Conversions.Functions.VolumeFlowRate_m3_s.from_gpm(370)
SI.Lengthdiameter_nominalSItf.Conversions.Functions.Distance_m.from_in(8.25)
Modelica.Units.NonSI.AngularVelocity_rpmN_nominal1160
SI.LengthdiameterSItf.Conversions.Functions.Distance_m.from_in(12.75)
SI.TemperatureT_nominalSItf.Conversions.Functions.Temperature_K.from_degF(70)
SI.Pressurep_nominal1e5
Medium.ThermodynamicStatestateMedium.setState_pT(p_nominal, T_nominal)
SI.Densityd_nominalMedium.density(state)
SI.PressureDifferencedp_nominalhead_nominal*Modelica.Constants.g_n*d_nominal
SI.Pressurep_sourcep_nominal
SI.Pressurep_sinkp_source + dp_nominal
SI.MassFlowRatem_flow_nominald_nominal*V_flow_nominal
Real[:,2]table_english[8.343828043, 531.377404; 16.80676215, 459.9351107; 24.60145005, 368.1722129; 31.4017375, 222.3206472; 32.45476602, 102.723644; 33.16456417, 0]
Real[:,2]table{{if j == 1 then SItf.Conversions.Functions.Distance_m.from_ft(table_english[i, j]) else SItf.Conversions.Functions.VolumeFlowRate_m3_s.from_gpm(table_english[i, j]) for j in 1:2} for i in 1:size(table_english, 1)}
Real[3,2]table_eta_english[103.614805, 0.5; 259.0936365, 0.74; 468.1280995, 0.5]
Real[3,2]table_eta{{if j == 1 then SItf.Conversions.Functions.VolumeFlowRate_m3_s.from_gpm(table_eta_english[i, j]) else table_eta_english[i, j] for j in 1:2} for i in 1:size(table_eta_english, 1)}

Components

TypeNameDefaultDescription
BoundaryConditions.Boundary_pTSink
BoundaryConditions.Boundary_pTSource
Pump_Controlledpump

Contents

NameDescription
Medium