modelMultiStageTurbine
Information
N-stage steam turbine with an extraction tap between each pair of stages.
The package's only turbine template — a parameterized generalization of the
retired fixed-count HP_turbine / LP_turbine: set
nStages and the array parameters
p_nominal (length nStages+1) and m_flow_nominal
(length nStages); the stage chain, the (nStages-1) tap volumes, and all
connects are generated by a for-loop, so the stage count is data, not
structure.
Topology (nStages = 3 shown):
port_a -> stage[1] -> vol[1] -> stage[2] -> vol[2] -> stage[3] -> port_b
| |
v drain_extract[1] v drain_extract[2]
Exhaust backflow (optional)
The turbine has no volume at port_b, so whatever enthalpy the connected
downstream volume offers on reverse flow enters the last stage directly. When that volume
is a lumped two-phase vessel (a condenser, a heater shell) its outflow is usually the bulk
mixture, mostly liquid. With use_vapourBackflow_b = true a
ReverseVapourEnthalpy
element is inserted at the exhaust, so reverse flow carries saturated-vapour enthalpy
instead. It is transparent in forward flow and not energy-conserving in reverse flow;
default false (the exhaust is connected directly, as before).
Stodola sizing and its validity envelope
Each stage's flow coefficient is derived from its own nominal point:
Kti = m_flow_nominal[i] / (√(p·ρ(p_nominal[i],
T_nominal[i])) · f(p_nominal[i+1]/p_nominal[i])). Two things must be
right per stage, and both have been got wrong in practice:
m_flow_nominal[i]must be the flow that stage carries — the inlet flow minus all upstream extractions — not the machine total. Sizing every stage to the total leaves the downstream ladder 8–12 % low.T_nominal[i]must be on the vapour side. Evaluating atTsat(p)−5returns the liquid density (~950 kg/m³), makingKt~30× too small so the stage acts as a near-closed orifice.
The default T_nominal assumes a near-saturated
expansion. Stage 1 uses T_in_nominal; stages 2..n use
Tsat(p) + dT_superheat_nominal. That suits saturated-steam (nuclear)
cycles. For a high-superheat (fossil) expansion the later stages are sized on the
wrong density — Kt goes as 1/√ρ, so the stage passes
√(ρactual/ρnominal) of its design flow and the
ladder walks. Measured on the unit test: a 773 K / 6 MPa inlet puts tap 1
+15.2 % off, against −3.6 % at 570 K.
Set T_nominal explicitly in that case — run once with the
default, read the settled stage inlet temperatures, feed them back.
See Examples.SteamTurbineStodolaTests.MultiStageTurbine_Test
(near-saturated, default sizing) and
MultiStageTurbine_Superheat_Test (high superheat with an explicit
T_nominal).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | nStages | 3 | Number of expansion stages |
| Real | eta_is | 0.85 | Isentropic efficiency (applied to every stage) |
| SI.Pressure[nStages + 1] | p_nominal | Boundary pressures {inlet, tap_1, ..., tap_(n-1), outlet}; the interior (nStages-1) values are the extraction-tap pressures. | |
| SI.MassFlowRate[nStages] | m_flow_nominal | Per-stage nominal through-flow (sets each stage Stodola coefficient). Stage i carries the inlet flow minus all upstream extractions — set each to the ACTUAL design through-flow, else the stage is mis-sized (see #74). | |
| SI.Temperature | T_in_nominal | 520 | Inlet temperature (stage 1) |
| SI.Volume | V_tap | 20 | Each extraction-tap node volume (buffers the IC steam-fill transient). |
| SI.Pressure[nStages + 1] | p_start | p_nominal | |
| SI.SpecificEnthalpy[nStages + 1] | h_start | cat(1, {Medium.specificEnthalpy_pT(p_start[1], T_in_nominal)}, {Medium.dewEnthalpy(Medium.setSat_p(p_start[i])) - 30e3 for i in 2:nStages}, {Medium.dewEnthalpy(Medium.setSat_p(p_start[nStages + 1])) - 50e3}) | |
| Advanced › Exhaust | |||
| Boolean | use_vapourBackflow_b | false | = true: reverse flow into the exhaust (port_b -> last stage) carries saturated-vapour enthalpy (see ReverseVapourEnthalpy) |
| Advanced › Stodola sizing | |||
| SI.Temperature | dT_superheat_nominal | 5 | Superheat above Tsat used for the DEFAULT T_nominal of stages 2..n |
| SI.Temperature[nStages] | T_nominal | cat(1, {T_in_nominal}, {Medium.saturationTemperature(p_nominal[i]) + dT_superheat_nominal for i in 2:nStages}) | Per-stage nominal inlet T for the Stodola Kt sizing (see the note above) |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| TRANSFORM.Fluid.Interfaces.FluidPort_Flow | port_a | Steam inlet | |
| TRANSFORM.Fluid.Interfaces.FluidPort_Flow | port_b | Steam exhaust | |
| TRANSFORM.Fluid.Interfaces.FluidPort_State[nStages - 1] | drain_extract | Mid-stage extraction taps (one between each pair of stages) | |
| Modelica.Mechanics.Rotational.Interfaces.Flange_a | shaft_a | ||
| Modelica.Mechanics.Rotational.Interfaces.Flange_b | shaft_b |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| TRANSFORM.Fluid.Machines.SteamTurbine[nStages] | stages | ||
| TRANSFORM.Fluid.Volumes.MixingVolume[nStages - 1] | vols | ||
| TRANSFORM.Fluid.Machines.ReverseVapourEnthalpy | exhaustBackflow | Optional exhaust element: reverse flow into the last stage is saturated vapour |
Contents
| Name | Description |
|---|---|