modelMultiStageTurbine

N-stage steam turbine with an extraction tap between each pair of stages

Information

N-stage steam turbine with an extraction tap between each pair of stages. The package's only turbine template — a parameterized generalization of the retired fixed-count HP_turbine / LP_turbine: set nStages and the array parameters p_nominal (length nStages+1) and m_flow_nominal (length nStages); the stage chain, the (nStages-1) tap volumes, and all connects are generated by a for-loop, so the stage count is data, not structure.

Topology (nStages = 3 shown):

  port_a -> stage[1] -> vol[1] -> stage[2] -> vol[2] -> stage[3] -> port_b
                          |                     |
                          v drain_extract[1]    v drain_extract[2]

Exhaust backflow (optional)

The turbine has no volume at port_b, so whatever enthalpy the connected downstream volume offers on reverse flow enters the last stage directly. When that volume is a lumped two-phase vessel (a condenser, a heater shell) its outflow is usually the bulk mixture, mostly liquid. With use_vapourBackflow_b = true a ReverseVapourEnthalpy element is inserted at the exhaust, so reverse flow carries saturated-vapour enthalpy instead. It is transparent in forward flow and not energy-conserving in reverse flow; default false (the exhaust is connected directly, as before).

Stodola sizing and its validity envelope

Each stage's flow coefficient is derived from its own nominal point: Kti = m_flow_nominal[i] / (√(p·ρ(p_nominal[i], T_nominal[i])) · f(p_nominal[i+1]/p_nominal[i])). Two things must be right per stage, and both have been got wrong in practice:

  • m_flow_nominal[i] must be the flow that stage carries — the inlet flow minus all upstream extractions — not the machine total. Sizing every stage to the total leaves the downstream ladder 8–12 % low.
  • T_nominal[i] must be on the vapour side. Evaluating at Tsat(p)−5 returns the liquid density (~950 kg/m³), making Kt ~30× too small so the stage acts as a near-closed orifice.

The default T_nominal assumes a near-saturated expansion. Stage 1 uses T_in_nominal; stages 2..n use Tsat(p) + dT_superheat_nominal. That suits saturated-steam (nuclear) cycles. For a high-superheat (fossil) expansion the later stages are sized on the wrong density — Kt goes as 1/√ρ, so the stage passes √(ρactual/ρnominal) of its design flow and the ladder walks. Measured on the unit test: a 773 K / 6 MPa inlet puts tap 1 +15.2 % off, against −3.6 % at 570 K. Set T_nominal explicitly in that case — run once with the default, read the settled stage inlet temperatures, feed them back.

See Examples.SteamTurbineStodolaTests.MultiStageTurbine_Test (near-saturated, default sizing) and MultiStageTurbine_Superheat_Test (high superheat with an explicit T_nominal).

Parameters

TypeNameDefaultDescription
IntegernStages3Number of expansion stages
Realeta_is0.85Isentropic efficiency (applied to every stage)
SI.Pressure[nStages + 1]p_nominalBoundary pressures {inlet, tap_1, ..., tap_(n-1), outlet}; the interior (nStages-1) values are the extraction-tap pressures.
SI.MassFlowRate[nStages]m_flow_nominalPer-stage nominal through-flow (sets each stage Stodola coefficient). Stage i carries the inlet flow minus all upstream extractions — set each to the ACTUAL design through-flow, else the stage is mis-sized (see #74).
SI.TemperatureT_in_nominal520Inlet temperature (stage 1)
SI.VolumeV_tap20Each extraction-tap node volume (buffers the IC steam-fill transient).
SI.Pressure[nStages + 1]p_startp_nominal
SI.SpecificEnthalpy[nStages + 1]h_startcat(1, {Medium.specificEnthalpy_pT(p_start[1], T_in_nominal)}, {Medium.dewEnthalpy(Medium.setSat_p(p_start[i])) - 30e3 for i in 2:nStages}, {Medium.dewEnthalpy(Medium.setSat_p(p_start[nStages + 1])) - 50e3})
Advanced › Exhaust
Booleanuse_vapourBackflow_bfalse= true: reverse flow into the exhaust (port_b -> last stage) carries saturated-vapour enthalpy (see ReverseVapourEnthalpy)
Advanced › Stodola sizing
SI.TemperaturedT_superheat_nominal5Superheat above Tsat used for the DEFAULT T_nominal of stages 2..n
SI.Temperature[nStages]T_nominalcat(1, {T_in_nominal}, {Medium.saturationTemperature(p_nominal[i]) + dT_superheat_nominal for i in 2:nStages})Per-stage nominal inlet T for the Stodola Kt sizing (see the note above)

Connectors

TypeNameDefaultDescription
TRANSFORM.Fluid.Interfaces.FluidPort_Flowport_aSteam inlet
TRANSFORM.Fluid.Interfaces.FluidPort_Flowport_bSteam exhaust
TRANSFORM.Fluid.Interfaces.FluidPort_State[nStages - 1]drain_extractMid-stage extraction taps (one between each pair of stages)
Modelica.Mechanics.Rotational.Interfaces.Flange_ashaft_a
Modelica.Mechanics.Rotational.Interfaces.Flange_bshaft_b

Components

TypeNameDefaultDescription
TRANSFORM.Fluid.Machines.SteamTurbine[nStages]stages
TRANSFORM.Fluid.Volumes.MixingVolume[nStages - 1]vols
TRANSFORM.Fluid.Machines.ReverseVapourEnthalpyexhaustBackflowOptional exhaust element: reverse flow into the last stage is saturated vapour

Contents

NameDescription
Medium