Libraries
.
TRANSFORM
.
HeatAndMassTransfer
.
Examples
.
ExamplesFrom_NellisAndKlein
.
ConveyorBeltDesign
OMC
latest
demo
☼
model
ConveyorBeltDesign
Example 3.1-1 Design of a conveyor belt pp. 307-309
Open the diagram
▶ Simulate in your browser
Extends from
Icons.Example
(Icon for runnable examples).
Components
Type
Name
Default
Description
Modelica.Blocks.Sources.Constant
L
Conveyor length
Modelica.Blocks.Sources.Constant
D
Diameter
Modelica.Blocks.Sources.Constant
alpha
Heat transfer coefficient
Modelica.Blocks.Sources.Constant
th
Thickness
Utilities.CharacteristicNumbers.Models.BiotNumber
biotNumber
Modelica.Blocks.Sources.RealExpression
V
Volume
Modelica.Blocks.Sources.RealExpression
As
Surface area for heat transfer: ignoring edge
Modelica.Blocks.Sources.Constant
lambda
Thermal conductivity
Modelica.Blocks.Sources.Constant
d
Density
Modelica.Blocks.Sources.Constant
cp
Heat capacity
Utilities.Visualizers.displayReal
display_tau_lumped
Utilities.Visualizers.displayReal
display_biot
Volumes.UnitVolume
plasticDisk
Resistances.Heat.Convection
convection
BoundaryConditions.Heat.Temperature
boundary
Modelica.Blocks.Sources.RealExpression
T
Disk temperature
Blocks.TimerTotal
timer
Modelica.Blocks.Logical.GreaterEqualThreshold
greaterEqualThreshold
Utilities.Visualizers.displayReal
display_time
Stops changing when T < T_max
Modelica.Blocks.Sources.RealExpression
uc
Conveyor velocity
Utilities.Visualizers.displayReal
display_u
Stops changing when T < T_max
Modelica.Blocks.Sources.Constant
Tmax
Maximum acceptable disk temperature
Modelica.Blocks.Sources.Constant
Tinf
Ambient temperature
Modelica.Blocks.Sources.Constant
Tini
Initial plastic disk temperature
Utilities.CharacteristicNumbers.Models.LumpedHeatTimeConstant
tau_lumped
Modelica.Blocks.Sources.RealExpression
T_boundary
Utilities.ErrorAnalysis.UnitTests
unitTests