modelPartialResistance
Base thermal resistance model
Extends from TRANSFORM.Fluid.Interfaces.Records.Visualization_showName.
Information
Base of the thermal resistances: the heat flow rate from port_a to port_b is (port_a.T - port_b.T)/R, and a class that extends it sets only R. The resistance stores no heat, so the heat flow rate is the same at both ports at every instant; Volumes.SimpleWall and DiscritizedModels.Conduction_1D are walls that store heat.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Visualization | |||
| Boolean | showName (from Visualization_showName) | true | = true to show the component name on the icon |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Interfaces.HeatPort_Flow | port_a | Heat port at one end of the resistance | |
| Interfaces.HeatPort_Flow | port_b | Heat port at the other end of the resistance |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| SI.ThermalResistance | R | Thermal resistance |