modelSimpleWall_noMedia

Lumped plane wall model with properties as inputs

Extends from BaseClasses.PartialVolume_noMedia.

Information

Plane wall with one temperature, between two heat ports, whose density, specific heat capacity and thermal conductivity are inputs. SimpleWall takes the properties from a material package instead.

Assumptions and limits

  • The energy balance has no term for the mass that a change of th, surfaceArea or d adds or removes during a run.

Use

  • d, cp and lambda are inputs, so they can be expressions of the wall temperature T. The stored energy is m*cp*(T - T_reference), so where cp depends on T, as the default does, the heat capacity of the wall is not m*cp.
  • R is split between the ports as in SimpleWall.

Parameters

TypeNameDefaultDescription
Visualization
BooleanshowName (from Visualization_showName)true= true to show the component name on the icon
Initialization › Dynamics
DynamicsenergyDynamics (from PartialVolume_noMedia)Dynamics.DynamicFreeInitialFormulation of energy balances
Initialization › Start Value: Temperature
SI.TemperatureT_start (from PartialVolume_noMedia)298.15Temperature
Advanced
SI.TemperatureT_reference (from PartialVolume_noMedia)273.15Reference temperature for zero internal energy
Advanced › Model Structure
BooleanexposeState_afalse= true to define T at port_a, false to define Q_flow
BooleanexposeState_bfalse= true to define T at port_b, false to define Q_flow

Connectors

TypeNameDefaultDescription
Interfaces.HeatPort_Flowport_aHeat port at one face of the wall
Interfaces.HeatPort_Flowport_bHeat port at the opposite face of the wall

Components

TypeNameDefaultDescription
SI.LengththWall thickness
SI.AreasurfaceAreaSurface area for heat transfer
SI.VolumeV (from PartialVolume_noMedia)Volume
SI.Densityd (from PartialVolume_noMedia)Density
SI.SpecificHeatCapacitycp (from PartialVolume_noMedia)Specific heat capacity
SI.TemperatureT (from PartialVolume_noMedia)Temperature
SI.Massm (from PartialVolume_noMedia)Mass
SI.InternalEnergyU (from PartialVolume_noMedia)Internal energy
SI.HeatFlowRateUb (from PartialVolume_noMedia)Net heat flow rate into the volume
SI.ThermalConductivitylambda-0.0469*T + 76.813Thermal conductivity
SI.ThermalResistanceRth/(lambda*surfaceArea)Thermal resistance
SI.HeatFlowRateQ_gen0Internal heat generation