modelLMTD_HX_Q
Calculate Q using LMTD method
Extends from TRANSFORM.HeatExchangers.BaseClasses.Partial_LMTD_HX.
Information
Assumption:
Side 1 is hot side (i.e,. if Q_flow < 0 then heat is going from Side 1 to Side 2)
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Boolean | counterCurrent (from Partial_LMTD_HX) | true | |
| Initialization › Start Value: Absolute Pressure | |||
| SI.AbsolutePressure | p_start_1 (from Partial_LMTD_HX) | Medium_1.p_default | Pressure |
| SI.AbsolutePressure | p_start_2 (from Partial_LMTD_HX) | Medium_2.p_default | Pressure |
| Initialization › Start Value: Temperature | |||
| SI.Temperature | T_start_1 (from Partial_LMTD_HX) | Medium_1.T_default | Temperature |
| SI.Temperature | T_start_2 (from Partial_LMTD_HX) | Medium_2.T_default | Temperature |
| Initialization | |||
| SI.MassFlowRate | m_flow_start_1 (from Partial_LMTD_HX) | 0 | Mass flow rate |
| SI.MassFlowRate | m_flow_start_2 (from Partial_LMTD_HX) | 0 | Mass flow rate |