modelSingularPressureLoss_KDR
Singular pressure loss
Information
Copyright © EDF 2002 - 2010
ThermoSysPro Version 2.0
This component model is documented in Sect. 13.4 of the ThermoSysPro book.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | K | 1.e-4 | Pressure loss coefficient |
| ThermoSysPro.Units.SI.Density | p_rho | 0 | If > 0, fixed fluid density |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| ThermoSysPro.WaterSteam.Connectors.FluidInlet | C1 | ||
| ThermoSysPro.WaterSteam.Connectors.FluidOutlet | C2 |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| ThermoSysPro.Units.SI.PressureDifference | deltaP | Singular pressure loss | |
| ThermoSysPro.Units.SI.MassFlowRate | Q | Mass flow rate | |
| ThermoSysPro.Units.SI.Density | rho | Fluid density | |
| ThermoSysPro.Units.SI.Temperature | T | Fluid temperature | |
| ThermoSysPro.Units.SI.AbsolutePressure | Pm | Average fluid pressure | |
| ThermoSysPro.Units.SI.SpecificEnthalpy | h | Fluid specific enthalpy |
Revisions
Authors
- Baligh El Hefni
- Daniel Bouskela