modelCISEPlant

Model of the CISE lab steam generator

Information

This is the model of the CISE steam generation plant described in the paper: F. Casella, A. Leva, "Modelica open library for power plant simulation: design and experimental validation", Proceedings of the 2003 Modelica Conference, Linkö eping, Sweden, 2003.

The geometric parameters are already set. The start values set in the model parameters are guess values around the nominal full load steady state (60 bar drum pressure).

This model cannot be simulated alone, as the boundary conditions (feedwater flowrate and enthalpy, steam valve opening, power to the risers and power to the superheater) are not set. See the CiseSim model instead.

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealOutputDrumPressure
Modelica.Blocks.Interfaces.RealOutputDrumLevel
Modelica.Blocks.Interfaces.RealInputFeedWaterFlow
Modelica.Blocks.Interfaces.RealInputRiserPower
Modelica.Blocks.Interfaces.RealInputValveOpening
Modelica.Blocks.Interfaces.RealInputSHPower
Modelica.Blocks.Interfaces.RealInputFeedWaterEnthalpy

Components

TypeNameDefaultDescription
FluidPh.DrumDrum
FluidPh.SourceMassFlowFeedWater
FluidPh.Flow1DFV2phDowncomer
FluidPh.Flow1DFV2phRisers
FluidPh.Flow1DFV2phPipe2Drum
FluidPh.SinkMassFlowBlowdown
FluidPh.Flow1DFVPipe2SH
FluidPh.Flow1DFV2phSH
FluidPh.Flow1DFV2phPipe2Valve
FluidPh.ValveVapValve
FluidPh.SinkPressureSink
Thermal.HeatSource1DFVHeatSourceSH
Thermal.HeatSource1DFVHeatSourceRisers
FluidPh.HeaderHeaderLower
FluidPh.HeaderHeaderUpper
Thermal.MetalTubeFVDowncomerWall
Thermal.MetalTubeFVRisersWalls
Thermal.MetalTubeFVPipe2DrumWall
Thermal.MetalTubeFVPipe2SHWall
Thermal.MetalTubeFVSHWall
Thermal.MetalTubeFVPipe2ValveWall
FluidPh.PressDropPressDrop
Systemsystem

Contents

NameDescription
Medium

Revisions