Model of a flat plate solar thermal collector
This component models a solar thermal collector according to the
ASHRAE93 test standard.
Notice
- As mentioned in EnergyPlus 7.0.0 Engineering Reference, the
SRCC incident angle modifier equation coefficients are only valid
for incident angles of 60 degrees or less. Because these curves
behave poorly for angles greater than 60 degrees the model does not
calculate either direct or diffuse solar radiation gains when the
incidence angle is greater than 60 degrees.
- By default, the estimated heat capacity of the collector
without fluid is calculated based on the dry mass and the specific
heat capacity of copper.
References
EnergyPlus 7.0.0 Engineering
Reference, October 13, 2011.
- December 13, 2023, by Michael Wetter.
Moved to Obsolete package.
This is for Buildings,
#3604.
- December 11, 2023, by Michael Wetter:
Corrected implementation of pressure drop calculation for the
situation where the collectors are in parallel, e.g., if
sysConfig ==
Buildings.Obsolete.Fluid.SolarCollectors.Types.SystemConfiguration.Parallel.
Changed assignment of computeFlowResistance to
final based on dp_nominal.
This is for Buildings,
#3597.
- September 16, 2021, by Michael Wetter:
Changed lat from being a parameter to an input from
weather bus.
This is for IBPSA,
#1477.
- December 17, 2017, by Michael Wetter:
Revised computation of heat loss.
This is for issue
1100.
- November 21, 2017, by Michael Wetter:
Corrected error in heat loss calculations that did not scale
correctly with nPanels.
This is for issue
1073.
- October 18, 2013, by Michael Wetter:
Removed duplicate connection.
- January 4, 2013, by Peter Grant:
First implementation.