ChlorideSaltReceiver models the heat transfer
characteristics of an external tubular receiver with a user-defined
geometry by employing simple energy and mass balances, an average
temperature for receiver external surface, and heat transfer
correlations. The receiver ChlorideSaltReceiver model has
the following connectors:
- A HeatPort interface. According to the Modelica sign
convention, a positive heat flow rate Q_flow (in Watts) is
considered to flow into the receiver.
- A Real_input for the ambient temperature (in K).
- An inlet FluidPort_a and an outlet FluidPort_b.
Each fluid connector has three stream variables (h_outflow,
Xi_outflow and C_outflow) associated with the flow variable m_flow.
These variables represent the specific enthalpy, the mass fractions
and the concentrations associated to m_flow <0.
The model requires to define the following parameters:a
Medium package from the Media library. The default
medium package is the MoltenSalt_ph.
- H_rcv: Receiver height, in meters. Default: 1.0
m.
- D_rcv: Receiver diameter, in meters. Default: 1.0
m.
- N_pa: Number of panels of the receiver. Default:
20
- D_tb: Outer diameter of receiver tubes, in meters.
Default: 25e-3 m (1 mm).
- t_tb: Wall thickness of receiver tubes, in meters.
Default: 1e-3 m (1 mm).
- ab: Coating absorptance of the receiver. Default:
1.0.
- em: Coating emmitance of the receiver. Default:
1.0.
- const_alpha: Boolean, true if external convective heat
transfer. Default: true.
- alpha: Heat transfer coefficient due to external
convection, in W/(m2.K). Default: 30.0 W/(m2.K).
Generated at 2026-04-15T18:18:36Z by OpenModelicaOpenModelica 1.26.3 using