modelFin
Fin convection resistance model
Extends from TRANSFORM.HeatAndMassTransfer.Resistances.Heat.BaseClasses.PartialResistance (Base thermal resistance model).
Information
Heat transfer from a fin to the fluid around it, as a resistance between the fin base and the fluid. The fin efficiency eta comes from a model in FinEfficiency, such as GenericFin, which also computes the matching fin surface area.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Visualization | |||
| Boolean | showName (from Visualization_showName) | true | = true to show the component name on the icon |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Interfaces.HeatPort_Flow | port_a (from PartialResistance) | Heat port at one end of the resistance | |
| Interfaces.HeatPort_Flow | port_b (from PartialResistance) | Heat port at the other end of the resistance |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| SI.ThermalResistance | R (from PartialResistance) | Thermal resistance | |
| SI.Efficiency | eta | Fin efficiency | |
| SI.Area | surfaceArea | Heat transfer surface area | |
| SI.CoefficientOfHeatTransfer | alpha | Convection heat transfer coefficient |